Loading…
Co-Creation of a Lanreotide Autogel/Depot Syringe for the Treatment of Acromegaly and Neuroendocrine Tumours Through Collaborative Human Factor Studies
Introduction Although the previous lanreotide autogel/depot syringe had been well received, feedback indicated that improvements could be made to make it more user-friendly. Additionally, the view that patients should have greater involvement in the research and development process is echoed by the...
Saved in:
Published in: | Advances in therapy 2019-12, Vol.36 (12), p.3409-3423 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Introduction
Although the previous lanreotide autogel/depot syringe had been well received, feedback indicated that improvements could be made to make it more user-friendly. Additionally, the view that patients should have greater involvement in the research and development process is echoed by the International Neuroendocrine Cancer Alliance. A series of studies aimed to develop and validate a new syringe that works better for patients, caregivers and healthcare professionals (HCPs) by involving these groups at key stages in the development and testing process.
Methods
The multicentre, international, human factor studies, consisted of four formative studies and one validation study. The formative studies collected patient, caregiver and HCP feedback on the lanreotide autogel/depot syringe on the market at the time, and on newly designed prototypes. The validation study was conducted to evaluate the final syringe to confirm that it can be used effectively and safely in the intended environment, by the intended user, for the intended purpose.
Results
Overall, 213 individuals participated in the studies; 145 contributed to the formative studies and 68 to the validation study. The validated new-generation syringe included several important updates compared with the lanreotide autogel/depot syringe currently on the market, including the flanges, which are now larger and have a better grip; the overcap, which is white, ridged, opaque and bigger; the plunger supports and the thermoformed tray. No participant hurt themselves or others during the validation study (although several misuses were reported), and all participants succeeded in delivering a complete dose and activating the safety system.
Conclusion
With collaboration, a new syringe was developed to meet the needs of patients, caregivers and HCPs, whilst ensuring lanreotide was delivered effectively and safely. These studies highlight the importance of involving patients, caregivers and HCPs in clinical evaluation studies to develop medical products that address their concerns and meet their needs.
Funding
Ipsen.
Plain Language Summary
Plain language summary available for this article. |
---|---|
ISSN: | 0741-238X 1865-8652 |
DOI: | 10.1007/s12325-019-01112-3 |