Loading…
Deep learning LI-RADS grading system based on contrast enhanced multiphase MRI for differentiation between LR-3 and LR-4/LR-5 liver tumors
To develop a deep learning (DL) method based on multiphase, contrast-enhanced (CE) magnetic resonance imaging (MRI) to distinguish Liver Imaging Reporting and Data System (LI-RADS) grade 3 (LR-3) liver tumors from combined higher-grades 4 and 5 (LR-4/LR-5) tumors for hepatocellular carcinoma (HCC) d...
Saved in:
Published in: | Annals of translational medicine 2020-06, Vol.8 (11), p.701-701 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | To develop a deep learning (DL) method based on multiphase, contrast-enhanced (CE) magnetic resonance imaging (MRI) to distinguish Liver Imaging Reporting and Data System (LI-RADS) grade 3 (LR-3) liver tumors from combined higher-grades 4 and 5 (LR-4/LR-5) tumors for hepatocellular carcinoma (HCC) diagnosis.
A total of 89 untreated LI-RADS-graded liver tumors (35 LR-3, 14 LR-4, and 40 LR-5) were identified based on the radiology MRI interpretation reports. Multiphase 3D T1-weighted gradient echo imaging was acquired at six time points: pre-contrast, four phases immediately post-contrast, and one hepatobiliary phase after intravenous injection of gadoxetate disodium. Image co-registration was performed across all phases on the center tumor slice to correct motion. A rectangular tumor box centered on the tumor area was drawn to extract subset tumor images for each imaging phase, which were used as the inputs to a convolutional neural network (CNN). The pre-trained AlexNet CNN model underwent transfer learning using liver MRI data for LI-RADS tumor grade classification. The output probability number closer to 1 or 0 indicated a higher possibility of being combined LR-4/LR-5 tumor or LR-3 tumor, respectively. Five-fold cross validation was used for training (60% dataset), validation (20%) and testing processes (20%).
The DL CNN model for LI-RADS grading using inputs of multiphase liver MRI data acquired at three time points (pre-contrast, arterial, and washout phase) achieved a high accuracy of 0.90, sensitivity of 1.0, precision of 0.835, and AUC of 0.95 with reference to the expert human radiologist report. The CNN output of probability provided radiologists a confidence level of the model's grading for each liver lesion.
An AlexNet CNN model for LI-RADS grading of liver lesions provided diagnostic performance comparable to radiologists and offered valuable clinical guidance for differentiating intermediate LR-3 liver lesions from more-likely malignant LR-4/LR-5 lesions in HCC diagnosis. |
---|---|
ISSN: | 2305-5839 2305-5839 |
DOI: | 10.21037/atm.2019.12.151 |