Loading…

Active Implantable cardioverter-defibrillators in Continuous-flow Left Ventricular Assist Device Recipients

Implantable cardioverter-defibrillator (ICD) in patients with heart failure with reduced ejection fraction reduces mortality secondary to malignant arrhythmias. Whether end-stage heart failure (HF) with continuous-flow left ventricular assist device (cf-LVAD) derive similar benefits remains controve...

Full description

Saved in:
Bibliographic Details
Published in:Journal of atrial fibrillation 2021-06, Vol.14 (1), p.20200490-20200490
Main Authors: Shah, Kuldeep, Chaudhary, Rahul, K Turagam, Mohit, Shah, Mahek, Patel, Brijesh, Lanier, Gregg, Lakkireddy, Dhanunjaya, Garg, Jalaj
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Implantable cardioverter-defibrillator (ICD) in patients with heart failure with reduced ejection fraction reduces mortality secondary to malignant arrhythmias. Whether end-stage heart failure (HF) with continuous-flow left ventricular assist device (cf-LVAD) derive similar benefits remains controversial. We performed a systematic literature review and meta-analysis of all published studies that examined the association between active ICDs and survival in advanced HF patients with cfLVAD. We searched PubMed, Medline, Embase, Ovid, and Cochrane for studies reporting the association between ICD and all-cause mortality in advanced HF patients with cfLVAD. Mantel-Haenszel risk ratio (RR) random-effects model was used to summarize data. Ten studies (9 retrospective and one prospective) with a total of 7,091 patients met inclusion criteria. There was no difference in all-cause mortality (RR 0.84, 95% CI 0.65-1.10, p=0.20, I =62.40%), likelihood of survival to transplant (RR 1.07, 95% CI 0.98-1.17, p= 0.13, I =0%), RV failure (RR 0.74, 95% CI 0.44-1.25, p = 0.26, I =34%) between Active ICD and inactive/no ICD groups, respectively. Additionally, 27.5% received appropriate ICD shocks, while 9.5% received inappropriate ICD shocks. No significant difference was observed in terms of any complications between the two groups. All-cause mortality, the likelihood of survival to transplant, and worsening RV failure were not significantly different between active ICD and inactive/no ICD in cf-LVAD recipients. A substantial number of patients received appropriate ICD shocks suggesting a high-arrhythmia burden. The risks and benefits of ICDs must be carefully considered in patients with cf-LVAD.
ISSN:1941-6911
1941-6911
DOI:10.4022/jafib.20200490