Loading…

Effect of total body irradiation lung block parameters on lung doses using three‐dimensional dosimetry

Purpose Total body irradiation (TBI) is an integral part of stem cell transplant. However, patients are at risk of treatment‐related toxicities, including radiation pneumonitis. While lung dose is one of the most crucial aspects of TBI dosimetry, currently available data are based on point doses. As...

Full description

Saved in:
Bibliographic Details
Published in:Journal of applied clinical medical physics 2022-04, Vol.23 (4), p.e13513-n/a
Main Authors: Luk, Samuel M. H., Wallner, Kent, Glenn, Mallory C., Ermoian, Ralph, Phillips, Mark H., Tseng, Yolanda D., Kim, Minsun
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Purpose Total body irradiation (TBI) is an integral part of stem cell transplant. However, patients are at risk of treatment‐related toxicities, including radiation pneumonitis. While lung dose is one of the most crucial aspects of TBI dosimetry, currently available data are based on point doses. As volumetric dose distribution could be substantially altered by lung block parameters, we used 3D dosimetry in our treatment planning system to estimate volumetric lung dose and measure the impact of various lung block designs. Materials and methods We commissioned a TBI beam model in RayStation that matches the measured tissue‐phantom ratio under our clinical TBI setup. Cerrobend blocks were automatically generated in RayStation on thoracic Computed Tomography (CT) scans from three anonymized patients using the lung, clavicle, spine, and diaphragmatic contours. The margin for block edge was varied to 0, 1, or 2 cm from the superior, lateral, and inferior thoracic borders, with a uniform margin 2.5 cm lateral to the vertebral bodies. The lung dose was calculated and compared with a prescription dose of 1200 cGy in six fractions (three with blocks and three without). Result The point dose at midplane under the block and the average lung dose are at the range of 73%–76% and 80%–88% of prescription dose respectively regardless of the block margins. In contrast, the percent lung volume receiving 10 Gy increased by nearly two‐fold, from 31% to 60% over the margins from 0 to 2 cm. Conclusions The TPS‐derived 3D lung dose is substantially different from the nominal dose assumed with HVL lung blocks. Point doses under the block are insufficient to accurately gauge the relationship between dose and pneumonitis, and TBI dosimetry could be highly variable between patients and institutions as more descriptive parameters are not included in protocols. Much progress remains to be made to optimize and standardize technical aspects of TBI, and better dosimetry could provide more precise dosimetric predictors for pneumonitis risk.
ISSN:1526-9914
1526-9914
DOI:10.1002/acm2.13513