Immediate Occlusal Loading of Single Lower Molars Using Brånemark System® Wide-Platform TiUnite™ Implants: An Interim Report of a Prospective Open-Ended Clinical Multicenter Study

ABSTRACT Background: First and second molars in the lower jaw are the most commonly missing teeth. As in other jaw regions with tooth loss, implant therapy is an attractive concept. Owing to the wide dimension of the molar teeth, wide implants seem to be a natural choice. However, wide implants in p...

Full description

Saved in:
Bibliographic Details
Published in:Clinical implant dentistry and related research 2003-03, Vol.5 (s1), p.74-80
Main Authors: Calandriello, Roberto, Tomatis, Massimiliano, Vallone, Roberto, Rangert, Bo, Gottlow, Jan
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:ABSTRACT Background: First and second molars in the lower jaw are the most commonly missing teeth. As in other jaw regions with tooth loss, implant therapy is an attractive concept. Owing to the wide dimension of the molar teeth, wide implants seem to be a natural choice. However, wide implants in posterior mandibular regions sometimes present a problem. As an oxidized surface seems to facilitate implant integration and to result in a stronger fixation to bone, it was hypothesized that this surface would improve the performance of wide implants in posterior mandibles. As high initial stability most often is achieved in this region, it was hypothesized that the load per se is not a problem. Purpose: The purpose of the present study is to evaluate immediate loading of Brånemark System® TiUnite™ Wide‐Platform implants (Nobel Biocare AB, Gothenburg, Sweden) supporting single molar crowns in the lower jaw. Materials and Methods: The study includes 44 patients treated in three separate private dental offices between March 2001 and June 2002. A total of 50 implants were placed, and all implants have passed the 6‐month follow‐up; 24 have been followed up for 1 year. All implants were provided with provisional crowns in centric occlusion at the time of surgery. Results: No implant has been lost. Marginal bone levels were found in accordance with normal biologic width requirements. Resonance frequency analysis showed high and consistent implant stability. No biomechanical problems were found associated with the use of wide implants, and the potential physiologic problem in dense mandibular bone was eliminated. Conclusion: Although limited by being a short‐term study, the result encourages immediate loading of single Brånemark System TiUnite Wide‐Platform implants placed in the molar regions in the lower jaw.
ISSN:1523-0899
1708-8208
DOI:10.1111/j.1708-8208.2003.tb00018.x